Metal seated gate valve with cap.

Metal seated gate valve with three-phase electric actuator.

Metal seated gate valve with manual reducer.

Metal seated gate valve with position indicator.

Metal closing gate valve with 1 opening limit switch.

Metal closing gate valve with 1 closing limit switch.

Metal seated gate valve with 2 limit switches.

Upon consultation: valve option with rings in stainless steel.

Metal Seated Gate Valve Fig. 31

– According to EN-1171.
– Face to face dimensions according to EN 558-1 Serie 14. DIN 3202 / F4.
– From DN 40 to DN 300, flanges dimensions and holes according to UNE-EN 1092-2 PN10.
– From DN 350 to DN 800, flanges dimensions according to UNE-EN 1092-2 PN16 and holes according to UNE-EN 1092-2 PN10 / PN16.

You must be logged in to download the technical sheet

Product details

Aplications , , , ,
Max. temperature

Aplications

Foot valves are commonly used in ponds, swimming pools, wells and almost anywhere there is a pump.

The surface or opening of the foot valve is larger than that of the pipe, thereby minimizing pressure loss (energy dissipated due to friction along the pipe).

Description

Our metal seated gate valve serves to stop or give complete passage to a fluid, it is bidirectional, and opens and closes the circuit using a wedge with a conical design. It has a concave housing at the bottom of the valve where sediments and impurities from the network are lodged and remain embedded in the wedge and are then released. These will be cleaned during maintenance or repair.

It is suitable for installation in those points where it must remain normally closed, since when the wedge fits into the body it presents a good seal under any circumstance and offers great durability. We will also use it when it comes to handling compressible fluids such as steam so that slow closing does not cause hydraulic phenomena that could damage the valve and the general system.

The standard packing is PTFE (Teflon®) for excellent sealing effect and anti-corrosion properties.

It is installed in pipelines as an isolation valve. Do not use it as a control or regulation valve. To close we will make a rotating movement of the steering wheel clockwise and counterclockwise to open. As it is an internal spindle valve, operation is carried out by means of a threaded spindle that does not go up or down, it only rotates and moves a wedge with metal rings up or down along with a spindle nut that is housed in its part. superior. It has a small head loss and a total passage which gives a low head loss.

The standard manually operated valve (with handwheel) being slow in operation will also avoid the effects of water hammer.