-Flange and hole dimensions according to: UNE-EN 1092-2 PN10 / PN16.
CHARACTERISTICS:
The air valve contains a kinetic valve and another valve for automatic air evacuation in a single body. In the sanitary system its function is to release and admit the air (gases) from the sewage water’s. The exclusive structure of this air valve guarantees the complete liquid split from the closure system and provide optimal working conditions. For a correct operation, the minimum working pressure must be at least 1,5 bar.
OPERATION:
During pipeline filling, the air pockets (gases) are reléase at high flow rates through the kinetic valve orifice.
It admits a large volume of air during the emptying of the pipelines. Under normal operating conditions, water streams with debris are in the line, and the kinetic valve orifice remains closed, because the release valve stops passing the air that accumulates through the automatic valve. The mechanism prevents the automatic nozzle opening at every small change of pressure in the line, and ensures a gap between the seal system and the contaminated liquid.
We manufacture any DN, PN, or special specification at our facility in Paterna.
Our technical team responds within 24 hours.
Utilizamos cookies propias y de terceros para garantizar el correcto funcionamiento del sitio web y, con tu consentimiento, analizar la navegación y mejorar nuestros servicios. Puedes aceptar, rechazar o configurar las cookies según tus preferencias. Consulta nuestra Política de Cookies para más información.